当前位置: X-MOL 学术Diabetes Technol. Ther. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Safety Event Outcomes and Glycemic Control with a Hybrid Closed-Loop System Used by Chinese Adolescents and Adults with Type 1 Diabetes Mellitus.
Diabetes Technology & Therapeutics ( IF 5.4 ) Pub Date : 2023-09-05 , DOI: 10.1089/dia.2023.0234
Yu Pei 1 , Weijian Ke 2 , Jing Lu 3 , Yi Lin 4 , Zhijian Zhang 4 , Yongde Peng 4 , Yan Bi 3 , Yanbing Li 2 , Jue Hou 5 , Xiaolu Zhang 6 , Xiaoxiao Chen 7 , Yuri Treminio 7 , Scott W Lee 7 , John Shin 7 , Andrew S Rhinehart 7 , Robert A Vigersky 7 , Yiming Mu 1
Affiliation  

Background: While evidence supports glycemic control benefits for individuals with type 1 diabetes mellitus (T1DM) using hybrid closed-loop (HCL) systems, HCL automated insulin delivery therapy in China has not been assessed. This study evaluated safety events and effectiveness during HCL system use by Chinese adolescents and adults with T1DM. Methods: Sixty-two participants (n = 12 adolescents with a mean ± standard deviation [SD] of 15.5 ± 1.1 years and n = 50 adults [mean ± SD of 37.6 ± 11.1 years]) with T1DM and baseline A1C of 7.1% ± 1.0% underwent a run-in period (∼2 weeks) using open-loop Manual Mode (sensor-augmented pump) insulin delivery with the MiniMed™ 770G system with the Guardian™ Sensor (3) glucose sensor, followed by a study period (4 weeks) with HCL Auto Mode enabled. Analyses compared continuous glucose monitoring data and insulin delivered during the run-in versus study period (Wilcoxon signed-rank test or t-test). Safety events included rates of severe hypoglycemia and diabetic ketoacidosis (DKA). Results: Compared to baseline run-in, overall Auto Mode use increased time in range (TIR, 70-180 mg/dL) from 75.3% to 80.9% (P < 0.001) and reduced time below range (TBR, <70 mg/dL) from 4.7% to 2.2% (P < 0.001). Subgroup analysis demonstrated that participants (n = 29) with baseline A1C <7.0% had TBR that reduced from 5.6% to 2.0%, while participants (n = 21) with baseline A1C ≥7.5% had time above range (TAR, >180 mg/dL) that reduced from 31.6% to 20.8%. Auto Mode use also increased the percentage achieving combined recommendations for time at sensor glucose ranges (i.e., TIR of >70%, TBR of <4% and TAR of <25%) from 24.2% at baseline to 77.4% at study end. Total daily insulin dose reduced from 42.8 ± 19.8 to 40.7 ± 18.9 U (P = 0.013). There were no severe hypoglycemic, DKA, or serious adverse events. Conclusions: Chinese adolescents and adults, some of whom met target A1C at baseline, safely achieved significantly improved glycemia with 1 month of MiniMed 770G system use when compared to open-loop insulin delivery. ClinicalTrials.gov ID: NCT04663295.
更新日期:2023-09-05
down
wechat
bug