Assessment of the change in the pH of water in a flow electric activator
Irrigation and Drainage ( IF 1.9 ) Pub Date : 2024-02-21 , DOI: 10.1002/ird.2938
Vladimir Storchevoy 1 , Mikhail Belov 1 , Dmitry Gurov 1 , Yuri Sudnik 1 , Nikolai Kabdin 1
Affiliation  

Soil pH is important for favourable plant growth. The water used for irrigation must have an optimal pH value. Such water can be prepared by passing it through a flow electric activator. An experimental setup with a flow electric activator was created to control the pH value of the activated water. A mathematical model was developed to establish the relationship between the activated water pH value and the power supply voltage and the performance of the anode and cathode chambers. The pH value of activated water varies in direct proportion to the power supply voltage and is inversely proportional to the performance of the set chambers. The pH value of activated water can be adjusted by two parameters: the voltage of the power source and the water supply.

中文翻译:

流电活化器中水 pH 值变化的评估

土壤 pH 值对于植物的良好生长非常重要。用于灌溉的水必须具有最佳的 pH 值。这种水可以通过将其通过流动电活化器来制备。创建了一个带有流动电活化器的实验装置来控制活化水的 pH 值。开发了数学模型来建立活化水pH值与电源电压以及阳极和阴极室性能之间的关系。活化水的pH值与电源电压成正比变化,与设定室的性能成反比。活化水的pH值可以通过两个参数来调节:电源电压和供水量。