Monte Carlo simulation of two Siemens Biograph PET/CT system using GATE: Image quality performance
Radiation Physics and Chemistry ( IF 2.9 ) Pub Date : 2024-03-01 , DOI: 10.1016/j.radphyschem.2024.111653
Rahal Saaidi , Abdelkrim Zeghari , Rajaa Cherkaoui El Moursli

The utilization of Monte Carlo simulation is a highly effective method in advancing research within the field of nuclear medicine. An important software tool for simulating and modeling cutting-edge systems for Positron Emission Tomography (PET) is the Geant4 Application for Tomographic Emission (GATE). This research specifically concentrates on two Siemens PET scanners: the Siemens Biograph True point (True V) and Siemens Biograph mcT 20 excel. Our primary objective was to validate the GATE V8.2 simulation in accordance with the NEMA (National Electrical Manufacturers Association) NU 2-2018 protocol, using a parallel computing platform on a local cluster of computers. This cluster was managed by the open-source package TORQUE version 6.1.0, which is based on the original wrapper PBS.

中文翻译:

使用 GATE 对两台西门子 Biograph PET/CT 系统进行蒙特卡洛模拟:图像质量性能

蒙特卡罗模拟的利用是推进核医学领域研究的一种非常有效的方法。 Geant4 断层扫描应用程序 (GATE) 是用于模拟和建模正电子发射断层扫描 (PET) 尖端系统的重要软件工具。这项研究特别关注两台西门子 PET 扫描仪:西门子 Biograph True point (True V) 和西门子 Biograph mcT 20 excel。我们的主要目标是根据 NEMA(美国电气制造商协会)NU 2-2018 协议,使用本地计算机集群上的并行计算平台来验证 GATE V8.2 模拟。该集群由开源软件包 TORQUE 版本 6.1.0 管理,该软件包基于原始包装器 PBS。