Skip to main content
Log in

Analyzing the Contraction Force of Artificial Muscles Under Negative Pressure Actuation

  • Research paper
  • Published:
Experimental Techniques Aims and scope Submit manuscript

Abstract

Artificial muscles actuated by negative pressure offer significant benefits over those driven by positive pressure, such as high contraction ratios and improved safety, making them a promising option for various applications. This paper studies the contraction force characteristic of a bellows-like artificial muscle actuated by negative pressure. Initially, the structure, fabrication, and working principle of the artificial muscle were introduced. Subsequently, based on the force balance method, the contraction force was decomposed as the forces acted by the difference value of the inner and the outer pressures on the end plate, and the tension force derived from the adjacent contraction unit. To reduce complexity, the contraction process was divided into three phases according to the distinct contact conditions of the contraction units: uncontacted, locally contacted, and fully contacted with crests. The deformations of the contraction units in each phase were analyzed, and the corresponding contraction forces were derived. An experiment platform was constructed to test the force by changing the dimension parameters and pressure, obtaining the output force data during isobaric contraction. Finally, a comparison of the experimental and calculated results substantiated the aptness of the theorem model.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19

Similar content being viewed by others

Data Availability

Data cannot be shared publicly, because data from this study may contain potentially or sensitive patient information.

References

  1. Tawk C, Spinks GM, Panhuis M, Alici G (2019) 3D Printable Linear Soft Vacuum Actuators: Their Modeling, Performance Quantification and Application in Soft Robotic Systems. IEEE/ASME Trans Mechatron 24(5):2118–2129

    Article  Google Scholar 

  2. Neiman VJ, Varghese S (2011) Synthetic bio-actuators and their applications in biomedicine. Smart Struct Syst 7(3):185–198

    Article  Google Scholar 

  3. Guan Q, Sun J, Liu Y et al (2021) Characterization and nonlinear models of bending extensile/contractile pneumatic artificial muscles[J]. Smart Materials and Structures 30(2):025024. https://doi.org/10.1088/1361-665X/abd4b0

    Article  Google Scholar 

  4. Tawk C, Panhuis M, Spinks GM, Alici G (2018) Bioinspired 3D printable soft vacuum actuators for locomotion robots. grippers and artificial muscles. Soft Robot 5(6):685–694

    Article  Google Scholar 

  5. Robertson MA, Paik J (2017) New soft robots really suck: Vacuum-powered systems empower diverse capabilities. Sci Robot 2(9):eaan6357

    Article  Google Scholar 

  6. Kelasidi E, Andrikopoulos G, Nikolakopoulos G et al (2011) A survey on pneumatic muscle actuators modeling. In: 2011 IEEE International Symposium on Industrial Electronics, Gdansk, Poland, pp 1263–1269

  7. Kalita B, Leonessa A, Dwivedy SK (2022) A review on the development of pneumatic artificial muscle actuators: Force model and application. Actuators 11(10):288

    Article  Google Scholar 

  8. Yi J, Chen X, Song C et al (2018) Fiber-reinforced origamic robotic actuator. Soft Robot 5(1):81

    Article  Google Scholar 

  9. Andrikopoulos G, Nikolakopoulos G, Manesis S (2016) Novel Considerations on Static Force Modeling of Pneumatic Muscle Actuators. IEEE/ASME Trans Mechatron 21(6):2647–2659

    Article  Google Scholar 

  10. Skorina EH, Luo M, Oo WY et al (2018) Reverse pneumatic artificial muscles (rPAMs): Modeling, integration, and control. PLoS ONE 13(10):e0204637

    Article  Google Scholar 

  11. Oguntosin V, Akindele A (2019) Design and characterization of artificial muscles from wedge-like pneumatic soft modules. Sens Actuators A Phys 297(1):111523

    Article  CAS  Google Scholar 

  12. Wirekoh J, Valle L, Pol N et al (2019) Sensorized, flat, pneumatic artificial muscle embedded with biomimetic microfluidic sensors for proprioceptive feedback. Soft Robot 6(6):768–777

    Article  Google Scholar 

  13. Ashwin KP, Ghosal A (2019) Static modeling of miniaturized pneumatic artificial muscles, kinematic analysis, and experiments on an endoscopic end-effector. IEEE/ASME Trans Mechatron 24(4):1429–1439

    Article  Google Scholar 

  14. Niiyama R, Sun X, Sung C et al (2015) Pouch motors: Printable soft actuators integrated with computational design. Soft Robot 2(2):59–70

    Article  Google Scholar 

  15. Felt W, Robertson MA and Paik J (2018) Modeling vacuum bellows soft pneumatic actuators with optimal mechanical performance. In: 2018 IEEE International Conference on Soft Robotics (RoboSoft), Livorno, Italy, pp 534–540

  16. Usevitch NS, Okamura AM and Hawkes EW (2018) APAM: Antagonistic Pneumatic Artificial Muscle. In: 2018 IEEE International Conference on Robotics and Automation (ICRA), Brisbane, QLD, Australia, pp 1539–1546

  17. Martens M, Boblan I (2017) Modeling the static force of a festo pneumatic muscle actuator: A new approach and a comparison to existing models. Actuators 6:33

    Article  Google Scholar 

  18. Alici G, Canty T, Mutlu R et al (2018) Modeling and experimental evaluation of bending behavior of soft pneumatic actuators made of discrete actuation chambers. Soft Robot 5(1):24–35

    Article  Google Scholar 

  19. Belforte G, Eula G, Ivanov A, Visan AL (2014) Bellows textile muscle. J Text Inst 105(3):356–364

    Article  Google Scholar 

  20. Xu Y, Fang Q, Li H (2021) Kinematic and quasi-static analysis model of a novel variable stiffness pneumatic artificial muscle. Sens Actuators A Phys 329:112815

    Article  CAS  Google Scholar 

  21. Yukisawa T, Ishii Y, Nishikawa S et al (2017) Modeling of extensible pneumatic actuator with bellows (EPAB) for continuum arm. In: 2017 IEEE International Conference on Robotics and Biomimetics (ROBIO). Macao, China, pp 2303–2308

  22. Wickramatunge KC, Leephakpreeda T (2010) Study on mechanical behaviors of pneumatic artificial muscle. Int J Eng Sci 48(2):188–198

    Article  Google Scholar 

  23. Li H, Kawashima K, Tadano K et al (2012) Achieving Haptic Perception in Forceps’ Manipulator Using Pneumatic Artificial Muscle. IEEE/ASME Trans Mechatron 18(1):74–85 (Akita, Japan)

    Article  CAS  Google Scholar 

  24. Cveticanin L, Zukovic M, Bíró I, Sárosi J (2018) Mathematical investigation of the stability condition and steady state position of a pneumatic artificial muscle – Mass system. Mech Mach Theory 125:196–206

    Article  Google Scholar 

  25. Han K, Kim NH, Shin D (2018) A novel soft pneumatic artificial muscle with high-contraction ratio. Soft Rob 5(5):554–566

    Article  Google Scholar 

  26. Hawkes EW, Christensen DL, Okamura AM (2016) Design and implementation of a 300% strain soft artificial muscle. In: 2016 IEEE International Conference on Robotics and Automation (ICRA), Stockholm, Sweden, pp 4022–4029

  27. Felt W (2019) An Inverting-Tube Clutching Contractile Soft Pneumatic Actuator

  28. Verrelst B, Ham RV, Vanderborght B et al (2006) Second generation pleated pneumatic artificial muscle and its robotic applications. Adv Robot 20(7):783–805

    Article  Google Scholar 

  29. Gough A, Hossain NMA, Jenkins C, Blandino J, Hendricks A (2005) Experimental and numerical study of creased membranes. In: 46th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics and Materials Conference

  30. Chou CP, Hannaford B (1996) Measurement and modeling of McKibben pneumatic artificial muscles. IEEE Trans Robot Automat 12(1):90–102

    Article  Google Scholar 

  31. Daerden F, Lefeber D (2002) Pneumatic artificial muscles: actuators for robotics and automation. Eur J Mech Environ Eng 47(1):10–21

    Google Scholar 

  32. Lee JG, Rodrigue H (2019) Origami-based vacuum pneumatic artificial muscles with large contraction ratios. Soft Robot 6(1):109–117

    Article  Google Scholar 

  33. Fox SI (2004) Human physiology, 8th edn. Higher Education/McGraw-Hill, Boston, p 342

    Google Scholar 

Download references

Acknowledgements

The work was supported by the National Natural Science Foundation Program under Grant 51775323.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Lei.

Ethics declarations

Conflict of Interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 123 KB)

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wu, Z., Zhao, P. & Lei, J. Analyzing the Contraction Force of Artificial Muscles Under Negative Pressure Actuation. Exp Tech (2023). https://doi.org/10.1007/s40799-023-00686-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s40799-023-00686-6

Keywords

Navigation