Posteroanterior Scout View of Pediatric Patients Using Computed Tomography During Different Tube Voltages: Validation Using Pediatric Anthropomorphic Phantoms

  • Original Paper
  • Published:
SN Comprehensive Clinical Medicine Aims and scope Submit manuscript

Abstract

This study aims to compare the effect of obtaining the anteroposterior scout view (APSV) with that of the posteroanterior scout view (PASV) on mammary gland dose in pediatric patients during different tube voltages. We used a pediatric anthropomorphic phantom with a 64 detector-row computed tomography (CT) scanner using the APSV or PASV protocol of the chest. A real-time skin dosimeter was placed on the scanner gantry and pasted onto the phantom surfaces of the right and left mammary glands. We compared the real-time skin dosimeter values in the right and left mammary glands between the APSV and PASV protocols at different tube voltages. Compared with APSV, it is possible to reduce the exposure dose by approximately 80% using PASV at different tube voltages (p < 0.05). Obtaining the PASV at 80, 100, and 120 kVp was useful in reducing the mammary gland dose by approximately 80% in pediatric patients compared with obtaining the APSV without deteriorating the image quality of the main scan.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Code Availability

Not applicable.

Abbreviations

CT :

Computed tomography

ATCM :

Automatic tube current modulation

APSV :

Anteroposterior scout view

PASV :

Posteroanterior scout view

SD :

Standard deviation

References

  1. Brenner DJ, Hall EJ. Computed tomography–an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–84.

    Article  CAS  PubMed  Google Scholar 

  2. Brenner D, Elliston C, Hall E, Berdon W. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol. 2001;176:289–96.

    Article  CAS  PubMed  Google Scholar 

  3. Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG, et al. Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children’s Hospital. AJR Am J Roentgenol. 2001;176:303–6.

    Article  CAS  PubMed  Google Scholar 

  4. Mettler FA Jr, Wiest PW, Locken JA, Kelsey CA. CT scanning: patterns of use and dose. J Radiol Prot. 2000;20:353–9.

    Article  PubMed  Google Scholar 

  5. The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction. Multidisciplinary conference organized by the Society of Pediatric Radiology. August 18–19, 2001. Pediatr Radiol. 2002;32(4):217–313.

  6. United States Nuclear Regulatory Commission. ALARA. Nuclear Regulatory Commission website. https://www.nrc.gov/reading-rm/basic-ref/glossary/alara.html. Accessed 19 Sept 2011.

  7. Amacker NA, Mader C, Alkadhi H, Leschka S, Frauenfelder T. Routine chest and abdominal high-pitch CT: an alternative low dose protocol with preserved image quality. Eur J Radiol. 2012;81:e392–7.

    Article  PubMed  Google Scholar 

  8. Szucs-Farkas Z, Schibler F, Cullmann J, Torrente JC, Patak MA, Raible S, et al. Diagnostic accuracy of pulmonary CT angiography at low tube voltage: intraindividual comparison of a normal-dose protocol at 120 kVp and a low-dose protocol at 80 kVp using reduced amount of contrast medium in a simulation study. AJR Am J Roentgenol. 2011;197:W852–9.

    Article  PubMed  Google Scholar 

  9. Kalra MK, Rizzo S, Maher MM, Halpern EF, Toth TL, Shepard JA, et al. Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology. 2005;237:303–8.

    Article  PubMed  Google Scholar 

  10. McKnight CD, Watcharotone K, Ibrahim M, Christodoulou E, Baer AH, Parmar HA. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination. Pediatr Radiol. 2014;44:997–1003.

    Article  PubMed  Google Scholar 

  11. Ronckers CM, Erdmann CA, Land CE. Radiation and breast cancer: a review of current evidence. Breast Cancer Res : BCR. 2005;7:21–32.

    Article  PubMed  Google Scholar 

  12. Masuda T, Shimizu Y, Kawazoe Y. Sakata Y [Dispatch Reports on Korean Society of Radiological Science Conference 2018 (KSRSC 2018)]. Nihon Hoshasen Gijutsu Gakkai zasshi. 2018;74:1109–12.

    Article  PubMed  Google Scholar 

  13. Peng W, Li Z, Xia C, Guo Y, Zhang J, Zhang K, et al. A CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation: phantom and patient study. Medicine. 2017;96:e7324.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Funama Y, Awai K, Nakayama Y, Kakei K, Nagasue N, Shimamura M, et al. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology. 2005;237:905–10.

    Article  PubMed  Google Scholar 

  15. Frush DP, Herlong JR. Pediatric thoracic CT angiography. Pediatr Radiol. 2005;35:11–25.

    Article  PubMed  Google Scholar 

  16. Masuda T, Funama Y, Nakaura T, Tahara M, Yamashita Y, Kiguchi M, et al. Radiation dose reduction with a low-tube voltage technique for pediatric chest computed tomographic angiography based on the contrast-to-noise ratio index. Can Assoc Radiol J. 2018;69:390–6.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Contributions

KA: conceived and designed the analysis, collected the data, contributed data or analysis tools, performed the analysis, wrote the paper.

TM: conceived and designed the analysis, collected the data, contributed data or analysis tools, performed the analysis, wrote the paper

YF: conceived and designed the analysis, collected the data, contributed data or analysis tools, wrote the paper

TN: conceived and designed the analysis, collected the data

TS: conceived and designed the analysis, collected the data

SM: conceived and designed the analysis, collected the data

TO: conceived and designed the analysis, collected the data

SA: conceived and designed the analysis, collected the data

AO: conceived and designed the analysis, collected the data

JH: conceived and designed the analysis, collected the data

KA: conceived and designed the analysis, collected the data

Corresponding author

Correspondence to Takanori Masuda.

Ethics declarations

Ethics Approval

This is the phantom study. This study was approved by the Institutional Review Board of Tsuchiya General Hospital.

Consent to Participate

Not applicable.

Conflict of Interest

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

This article is part of the Topical Collection on Medicine 

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Arao, K., Masuda, T., Funama, Y. et al. Posteroanterior Scout View of Pediatric Patients Using Computed Tomography During Different Tube Voltages: Validation Using Pediatric Anthropomorphic Phantoms. SN Compr. Clin. Med. 5, 282 (2023). https://doi.org/10.1007/s42399-023-01624-8

Download citation

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s42399-023-01624-8

Keywords

Navigation