Skip to main content
Log in

Accuracy of Advanced Pediatric Life Support Intubation Depth Formula in Indian Children Aged 1 to 12 Years

  • Research Paper
  • Published:
Indian Pediatrics Aims and scope Submit manuscript

Abstract

Objective

To evaluate the accuracy of the Advanced Pediatric Life Support (APLS) endotracheal tube (ET) depth formula in Indian children aged 1 to 12 years.

Methods

We enrolled 86 children aged 1–12 years requiring intubation and ventilation. The ET depth was determined using the APLS formula, and chest X-rays were utilized to evaluate ‘appropriate ET depth (accuracy)’ based on ‘vertebral level criteria’ and ‘safe distance between ET tip and carina.’

Results

Out of 86 cases, none had bronchial intubation. An accuracy of 37.2% (32 cases) was observed, with 57% (49 cases) showing deep placement. Among deep placements, 11 met ‘vertebral level criteria’ but not ‘safe distance criteria.’ Redefining deep placement based solely on ‘safe distance criteria,’ resulted in 50% accuracy.

Conclusion

APLS formula effectively prevents bronchial intubation in Indian children, but tends to overestimate ET depth (50% cases) when considering the ‘safe distance between ET tip and carina.’

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Pacheco-Lopez PC, Berkow LC, Hillel AT, Akst LM. Complications ofairway management. Respir Care. 2014;59: 1006–19.

    Article  PubMed  Google Scholar 

  2. Owen RL, Cheney FW. Endobronchial intubation: a preventable complication. Anesthesiology. 1987;67:255–7.

    Article  CAS  PubMed  Google Scholar 

  3. Weiss M, Knirsch W, Kretschmar O, et al. Tracheal tube-tip displacement in children during head-neck movement-a radiological assessment. Br J Anaesth. 2006;96:486–91.

    Article  CAS  PubMed  Google Scholar 

  4. Propst EJ, Gorodensky JH, Wolter NE. Length of the cricoid and trachea in children: predicting intubation depth to prevent subglottic stenosis. Laryngoscope. 2022;132:S1–S10.

    Article  PubMed  Google Scholar 

  5. Mackway-Jones K, Molyneux E, Phillips B, Wieteska S. Advanced life support group. Advanced Paediatric Life Support. The Practical Approach, 4th Ed. Blackwell publishing; 2005.p.40.

  6. Ng A, Ngiam N. Advanced paediatric airway management - As and Bs ofresuscitation. Advanced Paediatric Life Support Course (Singapore). Singapore Paediatric Society; 2016. p.20–38.

  7. Freeman JA, Fredricks BJ, Best CJ. Evaluation of a new method for determining tracheal tube length in children. Anaesthesia. 1995;50:1050–2.

    Article  CAS  PubMed  Google Scholar 

  8. Salem MR. Verification of endotracheal tube position. Anesthesiol Clin North Am. 2001;19:813–39.

    Article  CAS  PubMed  Google Scholar 

  9. Sivit CJ, Taylor GA, Hauser GJ, et al. Efficacy of chest radiography in pediatric intensive care. Am J Roentgenol. 1989;152:575–7.

    Article  CAS  Google Scholar 

  10. Zhou QH, Xiao WP, Zhou HM. Middle finger length based tracheal intubation depth improves the rate of appropriate tube placement in children. Paediatr Anaesth. 2015;25:1132–8.

    Article  PubMed  Google Scholar 

  11. Koshy T, Misra S, Chatterjee N, Dharan BS. Accuracy of a chest X-ray-based method for predicting the depth of insertion of endotracheal tubes in pediatric patients undergoing cardiac surgery. J Cardiothorac Vasc Anesth. 2016;30:947–53.

    Article  PubMed  Google Scholar 

  12. Pek JH, Tan EM, Hao Y, Ong GY. Comparison of formulae for orotracheal intubation depth in the paediatric population. Ann Acad Med Singap. 2018;47:138–42.

    Article  PubMed  Google Scholar 

  13. Neunhoeffer F, Wahl T, Hofbeck M, et al. A new method for determining the insertion depth oftracheal tubes in children: a pilot study. Br J Anaesth. 2016;116:393–7.

    Article  CAS  PubMed  Google Scholar 

  14. Volsko TA, McNinch NL, Prough DS, Bigham MT. Adherence to endotracheal tube depth guidelines and incidence of malposition in infants and children. Respir Care. 2018;63:1111–7.

    Article  PubMed  Google Scholar 

  15. Lau N, Playfor SD, Rashid A, Dhanarass M. New formulae for predicting tracheal tube length. Paediatr Anaesth. 2006;16:1238–43.

    Article  PubMed  Google Scholar 

Download references

Funding

Funding: None

Author information

Authors and Affiliations

Authors

Contributions

Contributors: VK: conceived the idea; SA, VK: conceptualized the study and devised its design; SA, MG, K: collected the data; BP, SB: analyzed and interpreted the data and provided critical inputs; VK, BP, SB: supervised data collection and helped in the conduct of the study; SA, MG, K: drafted the manuscript. VK, BP, SB: critically reviewed and revised the manuscript. All the authors read and approved the final manuscript, and agree to be accountable for all aspects of the study.

Corresponding author

Correspondence to Vishal Kumar.

Ethics declarations

Ethical clearance: Institutional Ethics Committee, ABVIMS & Dr RML Hospital, New Delhi; No. IEC/ABVIMS/RMLH714/19, dated Oct 22, 2019.

Competing interests: None stated.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Agrawal, S., Kumar, V., Gangwal, M. et al. Accuracy of Advanced Pediatric Life Support Intubation Depth Formula in Indian Children Aged 1 to 12 Years. Indian Pediatr 60, 997–1000 (2023). https://doi.org/10.1007/s13312-023-3062-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13312-023-3062-3

Keywords

Navigation