Abstract
In orthopedic and dental surgery, the implantation of biomaterials within the bone to restore the integrity of the treated organ has become a standard procedure. Their long-term stability relies on the osseointegration phenomena, where bone grows onto and around metallic implants, creating a bone-implant interface. Bone is a highly hierarchical material that evolves spatially and temporally during this healing phase. A deeper understanding of its biomechanical characteristics is needed, as they are determinants for surgical success. In this context, we propose a multiscale homogenization model to evaluate the effective elastic properties of bone as a function of the distance from the implant, based on the tissue’s structure and composition at lower scales. The model considers three scales: hydroxyapatite foam (nanoscale), ultrastructure (microscale), and tissue (mesoscale). The elastic properties and the volume fraction of the elementary constituents of bone matrix (mineral, collagen, and water), the orientation of the collagen fibril relative to the implant surface, and the mesoscale porosity constitute the input data of the model. The effect of a spatiotemporal variation in the collagen fibrils’ orientation on the bone anisotropic properties in the proximity of the implant was investigated. The findings revealed a strong variation of the components of the effective elasticity tensor of the bone as a function of the distance from the implant. The effective elasticity appears to be primarily sensitive to the porosity (mesoscale) rather than to the collagen fibrils’ orientation (sub-micro scale). However, the orientation of the fibrils has a significant influence on the isotropy of the bone. When analyzing the symmetry properties of the effective elasticity tensor, the ratio between the isotropic and hexagonal components is determined by a combination of the porosity and the fibrils’ orientation. A decrease in porosity leads to a decrease in bone isotropy and, in turn, an increase in the impact of the fibrils’ orientation. These results demonstrate that the collagen fibril orientation should be taken into account to properly describe the effective elastic anisotropy of bone at the organ scale.
Similar content being viewed by others
Availability of data and materials
The data that support the findings of this study are available from the corresponding author upon request.
References
Albrektsson T, Brånemark PI, Hansson HA et al (1981) Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 52(2):155–170. https://doi.org/10.3109/17453678108991776
Albrektsson T, Chrcanovic B, Östman P et al (2017) Initial and long-term crestal bone responses to modern dental implants. Periodontol 2000 73(1):41–50. https://doi.org/10.1111/prd.12176
Allen MR, Burr DB (2014) Bone modeling and remodeling. In: Burr DB, Allen MR (eds) Basic and applied bone biology. Academic Press, San Diego, pp 75–90. https://doi.org/10.1016/B978-0-12-416015-6.00004-6
Amengual-Peñafiel L, Brañes-Aroca M, Marchesani-Carrasco F et al (2019) Coupling between osseointegration and mechanotransduction to maintain foreign body equilibrium in the long-term: a comprehensive overview. J Clin Med 8(2):139. https://doi.org/10.3390/jcm8020139
Barkaoui A, Chamekh A, Merzouki T et al (2013) Multiscale approach including microfibril scale to assess elastic constants of cortical bone based on neural network computation and homogenization method. Int J Numer Methods Biomed Eng 30(3):318–338. https://doi.org/10.1002/cnm.2604
Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24(6):1679–1691. https://doi.org/10.1148/rg.246045065. (pMID: 15537976)
Browaeys JT, Chevrot S (2004) Decomposition of the elastic tensor and geophysical applications. Geophys J Int 159(2):667–678. https://doi.org/10.1111/j.1365-246X.2004.02415.x
Broz J, Simske S, Greenberg A (1995) Material and compositional properties of selectively demineralized cortical bone. J Biomech 28(11):1357–1368. https://doi.org/10.1016/0021-9290(94)00184-6ISTEX
Bünger MH, Oxlund H, Hansen TK et al (2010) Strontium and bone nanostructure in normal and ovariectomized rats investigated by scanning small-angle X-ray scattering. Calcif Tissue Int 86(4):294–306. https://doi.org/10.1007/s00223-010-9341-8
Cai X, Brenner R, Peralta L et al (2019) Homogenization of cortical bone reveals that the organization and shape of pores marginally affect elasticity. J R Soc Interface 16(151):20180,911. https://doi.org/10.1098/rsif.2018.0911
Chevalier Y, Pahr D, Allmer H et al (2007) Validation of a voxel-based Fe method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation. J Biomech 40(15):3333–3340. https://doi.org/10.1016/j.jbiomech.2007.05.004
Chrcanovic B, Kisch J, Albrektsson T et al (2016) Factors influencing early dental implant failures. J Dent Res 95(9):995–1002. https://doi.org/10.1177/0022034516646098
Colloca M, Blanchard R, Hellmich C et al (2014) A multiscale analytical approach for bone remodeling simulations: linking scales from collagen to trabeculae. Bone 64:303–313. https://doi.org/10.1016/j.bone.2014.03.050
Cowin SC (2001) Bone mechanics handbook, 2nd edn. CRC Press, Boca Raton. https://doi.org/10.1201/b14263
Fontaine KR, Barofsky I (2001) Obesity and health-related quality of life. Obes Rev 2(3):173–182. https://doi.org/10.1046/j.1467-789x.2001.00032.x
Gagliardi D, Sansalone V, Desceliers C et al (2018) Estimation of the effective bone-elasticity tensor based on CT imaging by a stochastic model. A multi-method validation. Eur J Mech A Solids 69:147–167. https://doi.org/10.1016/j.euromechsol.2017.10.004
Gao X, Sevostianov I (2016) Connection between elastic and electrical properties of cortical bone. J Biomech 49(5):765–772. https://doi.org/10.1016/j.jbiomech.2016.02.019
Gao X, Fraulob M, Haïat G (2019) Biomechanical behaviours of the bone-implant interface: a review. J R Soc Interface 16(156):20190,259. https://doi.org/10.1098/rsif.2019.0259
Georgiadis M, Müller R, Schneider P (2016) Techniques to assess bone ultrastructure organization: orientation and arrangement of mineralized collagen fibrils. J R Soc Interface 13(119):20160,088. https://doi.org/10.1098/rsif.2016.0088
Grisar K, Sinha D, Schoenaers J et al (2017) Retrospective analysis of dental implants placed between 2012 and 2014: indications, risk factors, and early survival. Int J Oral Maxillofac Implants 32(3):649–654. https://doi.org/10.11607/jomi.5332
Hamed E, Jasiuk I (2012) Elastic modeling of bone at nanostructural level. Mater Sci Eng R Rep 73(3–4):27–49. https://doi.org/10.1016/j.mser.2012.04.001
Hamed E, Lee Y, Jasiuk I (2010) Multiscale modeling of elastic properties of cortical bone. Acta Mech 213(1–2):131–154. https://doi.org/10.1007/s00707-010-0326-5
Hamed E, Jasiuk I, Yoo A et al (2012) Multi-scale modelling of elastic moduli of trabecular bone. J R Soc Interface 9(72):1654–1673. https://doi.org/10.1098/rsif.2011.0814
Haïat G, Padilla F, Peyrin F et al (2007) Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a 3d model simulation. J Bone Miner Res 22(5):665–674. https://doi.org/10.1359/jbmr.070209
Haïat G, Padilla F, Peyrin F et al (2008) Fast wave ultrasonic propagation in trabecular bone: numerical study of the influence of porosity and structural anisotropy. J Acoust Soc Am 123(3):1694–1705. https://doi.org/10.1121/1.2832611
Haïat G, Wang HL, Brunski J (2014) Effects of biomechanical properties of the bone-implant interface on dental implant stability: from in silico approaches to the patient’s mouth. Annu Rev Biomed Eng 16(1):187–213. https://doi.org/10.1146/annurev-bioeng-071813-104854
Hellmich C, Barthélémy JF, Dormieux L (2004) Mineral-collagen interactions in elasticity of bone ultrastructure - a continuum micromechanics approach. Eur J Mech A Solids 23(5):783–810. https://doi.org/10.1016/j.euromechsol.2004.05.004ISTEX
Hellmich C, Ulm FJ, Dormieux L (2004) Can the diverse elastic properties of trabecular and cortical bone be attributed to only a few tissue-independent phase properties and their interactions? Biomech Model Mechanobiol 2(4):219–238. https://doi.org/10.1007/s10237-004-0040-0
Hellmich C, Kober C, Erdmann B (2008) Micromechanics-based conversion of ct data into anisotropic elasticity tensors, applied to Fe simulations of a mandible. Ann Biomed Eng 36(1):108–122. https://doi.org/10.1007/s10439-007-9393-8
Hellmich C, Ukaj N, Smeets B et al (2022) Hierarchical biomechanics: concepts, bone as prominent example, and perspectives beyond. Appl Mech Rev. https://doi.org/10.1115/1.4055032
Hoerth RM, Katunar MR, Sanchez AG et al (2014) A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality. J Mater Sci Mater Med 25(2):411–422. https://doi.org/10.1007/s10856-013-5074-3
Hoerth RM, Seidt BM, Shah M et al (2014) Mechanical and structural properties of bone in non-critical and critical healing in rat. Acta Biomater 10(9):4009–4019. https://doi.org/10.1016/j.actbio.2014.06.003
Kaw AK (2019) Mechanics of composite materials. CRC Press, Boca Raton. https://doi.org/10.1201/9781420058291
Kurtz SM, Ong KL, Schmier J et al (2007) Future clinical and economic impact of revision total hip and knee arthroplasty. J Bone Joint Surge 89(suppl 3):144–151. https://doi.org/10.2106/jbjs.g.00587
Laws N (1977) The determination of stress and strain concentrations at an ellipsoidal inclusion in an anisotropic material. J Elast 7(1):91–97. https://doi.org/10.1007/BF00041133
Laws N (1977) A note on interaction energies associated with cracks in anisotropic solids. Phil Mag 36(2):367–372. https://doi.org/10.1080/14786437708244940
Laws N (1985) A note on penny-shaped cracks in transversely isotropic materials. Mech Mater 4(2):209–212. https://doi.org/10.1016/0167-6636(85)90017-1
Le Cann S, Törnquist E, Barreto IS et al (2020) Spatio-temporal evolution of hydroxyapatite crystal thickness at the bone-implant interface. Acta Biomater 116:391–399. https://doi.org/10.1016/j.actbio.2020.09.021
Liu Y, Manjubala I, Schell H et al (2010) Size and habit of mineral particles in bone and mineralized callus during bone healing in sheep. J Bone Miner Res 25(9):2029–2038. https://doi.org/10.1002/jbmr.84
Martínez-Reina J, Domínguez J, García-Aznar JM (2011) Effect of porosity and mineral content on the elastic constants of cortical bone: a multiscale approach. Biomech Model Mechanobiol 10(3):309–322. https://doi.org/10.1007/s10237-010-0236-4
Mathavan N, Turunen MJ, Guizar-Sicairos M et al (2018) The compositional and nano-structural basis of fracture healing in healthy and osteoporotic bone. Sci Rep 8(1):1591. https://doi.org/10.1038/s41598-018-19296-z
Nemat-Nasser S, Hori M (2013) Micromechanics: overall properties of heterogeneous materials. Elsevier, Amsterdam
Parnell WJ (2016) The Eshelby, hill, moment and concentration tensors for ellipsoidal inhomogeneities in the Newtonian potential problem and linear elastostatics. J Elast 125(2):231–294. https://doi.org/10.1007/s10659-016-9573-6
Pistoia W, Bv Rietbergen, Laib A et al (2001) High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo FE analysis of bone. J Biomech Eng 123(2):176–183. https://doi.org/10.1115/1.1352734
Podshivalov L, Fischer A, Bar-Yoseph P (2011) 3D hierarchical geometric modeling and multiscale FE analysis as a base for individualized medical diagnosis of bone structure. Bone 48(4):693–703. https://doi.org/10.1016/j.bone.2010.12.022
Podshivalov L, Fischer A, Bar-Yoseph P (2011) Multiscale FE method for analysis of bone micro-structures. J Mech Behav Biomed Mater 4(6):888–899. https://doi.org/10.1016/j.jmbbm.2011.03.003
Reznikov N, Bilton M, Lari L et al (2018) Fractal-like hierarchical organization of bone begins at the nanoscale. Science 360(6388):2189. https://doi.org/10.1126/science.aao2189
Bv Rietbergen, Ito K (2015) A survey of micro-finite element analysis for clinical assessment of bone strength: The first decade. J Biomech 48(5):832–841. https://doi.org/10.1016/j.jbiomech.2014.12.024
Rietbergen BV, Odgaard A, Kabel J et al (1996) Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. J Biomech 29(12):1653–1657. https://doi.org/10.1016/s0021-9290(96)80021-2
Rietbergen BV, Odgaard A, Kabel J et al (1998) Relationships between bone morphology and bone elastic properties can be accurately quantified using high-resolution computer reconstructions. J Orthop Res 16(1):23–28. https://doi.org/10.1002/jor.1100160105
Rodriguez-Florez N, Oyen ML, Shefelbine SJ (2014) Age-related changes in mouse bone permeability. J Biomech 47(5):1110–1116. https://doi.org/10.1016/j.jbiomech.2013.12.020
Sansalone V, Naili S, Bousson V et al (2010) Determination of the heterogeneous anisotropic elastic properties of human femoral bone: from nanoscopic to organ scale. J Biomech 43(10):1857–1863. https://doi.org/10.1016/j.jbiomech.2010.03.034
Sansalone V, Bousson V, Naili S et al (2012) Anatomical distribution of the degree of mineralization of bone tissue in human femoral neck: impact on biomechanical properties. Bone 50(4):876–884. https://doi.org/10.1016/j.bone.2011.12.020
Shah FA, Thomsen P, Palmquist A (2019) Osseointegration and current interpretations of the bone-implant interface. Acta Biomater 84:1–15. https://doi.org/10.1016/j.actbio.2018.11.018
Suquet P (1997) Continuum micromechanics. Springer, Vienna. https://doi.org/10.1007/978-3-7091-2662-2
Turunen MJ, Kaspersen JD, Olsson U et al (2016) Bone mineral crystal size and organization vary across mature rat bone cortex. J Struct Biol 195(3):337–344. https://doi.org/10.1016/j.jsb.2016.07.005
Törnquist E, Isaksson H, Turunen MJ (2020) Mineralization of cortical bone during maturation and growth in rabbits. J Bone Miner Metab 38(3):289–298. https://doi.org/10.1007/s00774-019-01068-y
Törnquist E, Cann SL, Tudisco E et al (2021) Dual modality neutron and x-ray tomography for enhanced image analysis of the bone-metal interface. Phys Med Biol 66(13):135,016. https://doi.org/10.1088/1361-6560/ac02d4
Ulrich D, Bv Rietbergen, Laib A et al (1999) The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 25(1):55–60. https://doi.org/10.1016/s8756-3282(99)00098-8
Vaughan T, McCarthy C, McNamara L (2012) A three-scale finite element investigation into the effects of tissue mineralisation and lamellar organisation in human cortical and trabecular bone. J Mech Behav Biomed Mater 12:50–62. https://doi.org/10.1016/j.jmbbm.2012.03.003
Wagermaier W, Gourrier A, Aichmayer B (2013) Materials design inspired by nature : function through inner architecture. Smart Materials Series pp 46–73. https://doi.org/10.1039/9781849737555-00046
Walker AM, Wookey J (2012) MSAT-a new toolkit for the analysis of elastic and seismic anisotropy. Comput Geosci 49:81–90. https://doi.org/10.1016/j.cageo.2012.05.031
Wirth AJ, Goldhahn J, Flaig C et al (2011) Implant stability is affected by local bone microstructural quality. Bone 49(3):473–478. https://doi.org/10.1016/j.bone.2011.05.001ISTEX
Zaoui A (2002) Continuum micromechanics: survey. J Eng Mech 128(8):808–816. https://doi.org/10.1061/(ASCE)0733-9399(2002)128:8(808)
Acknowledgements
This work has been supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement no. 101027554. This project has received funding from the project OrthAncil (ANR-21-CE19-0035-03) and from the project OrthoMat (ANR-21-CE17-0004).
Funding
No funding was received to assist with the preparation of this manuscript.
Author information
Authors and Affiliations
Contributions
LC provided software and contributed to methodology, computations, validation, writing—original draft preparation, review, and editing. SN was involved in conceptualization, methodology, writing—review, and editing. SLC contributed to data curation, validation, writing—review, and editing. GH was involved in supervision, conceptualization, writing—review, and editing.
Corresponding author
Ethics declarations
Conflict of interest
On behalf of all authors, the corresponding author states that there is no conflict of interest.
Ethics approval
Not approval
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Colabella, L., Naili, S., Le Cann, S. et al. Effect of collagen fibril orientation on the anisotropic properties of peri-implant bone. Biomech Model Mechanobiol (2024). https://doi.org/10.1007/s10237-023-01811-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10237-023-01811-5